1 option
Adaptive Speed-Regulated Impedance Control for Robotic Ultrasound Scanning: Reducing Constant-Force Tracking Errors Hefei University of Technology
- Format:
- Book
- Conference/Event
- Author/Creator:
- Min, Kang, author.
- Zhang, Le, author.
- Shi, Yudong, author.
- Fang, Jin, author.
- Mo, Hangjie, author.
- Li, Xiaojian, author.
- Conference Name:
- Interntional Conference on the New Energy and Intelligent Vehicles (2025-11-02 : Hefei, China)
- Language:
- English
- Subjects (All):
- Data acquisition and handling.
- Robotics.
- Imaging and visualization.
- Splines.
- Research and development.
- Standardization.
- Local Subjects:
- Data acquisition and handling.
- Robotics.
- Imaging and visualization.
- Splines.
- Research and development.
- Standardization.
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2026
- Summary:
- Robotic ultrasound scanning technology is a research hotspot in the field of medical imaging, and can achieve standardized and high-precision data acquisition. However, large force tracking errors occur during scanning, especially in complex human tissues, which can severely degrade image quality and diagnostic accuracy. Therefore, we propose an adaptive speed-regulated impedance control strategy to address this challenge, which innovatively combines the spline real-time interpolation and impedance control for constant force tracking. Firstly, the discrete ultrasound scanning paths are fitted to generate a smooth and synchronized interpolation trajectory. Then, the speed of the reference trajectory is adjusted in real time based on the Taylor formula to reduce the force tracking error. Experimental verification was conducted, and the results showed that the force tracking error increases with the increase of trajectory speed. In addition, at high speeds (e.g., 10 mm/s), the mean/variance of the force tracking error of the proposed method (0.3067N/0.2784) is reduced by 31.1%/37.4% respectively compared with the mean/variance of the traditional impedance control (0.4452N/0.4448), fully demonstrating the effectiveness of the proposed control strategy
- Notes:
- Vendor supplied data
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.