My Account Log in

1 option

Test No. 223: Avian Acute Oral Toxicity Test [electronic resource] / Organisation for Economic Co-operation and Development

OECD Global Available online

View online
Format:
Book
Government document
Author/Creator:
Organisation for Economic Co-operation and Development.
Series:
OECD Guidelines for the Testing of Chemicals, Section 2, 20745761.
Language:
English
Subjects (All):
Environment.
Local Subjects:
Environment.
Physical Description:
1 online resource (28 p.)
Place of Publication:
Paris : OECD Publishing, 2016.
Summary:
This Test Guideline describes procedures designed to estimate the acute oral toxicity of substances to birds, and it provides three testing options: (1) limit dose test, (2) LD50-slope test, and (3) LD50-only test. The LD50-slope and LD50-only options are sequential testing procedures. The test method selected will depend on whether or not a definitive median dose (LD50) and slope of the dose-response curve are both needed. The limit dose test is the preferred test when toxicity is expected to be low and lethality is unlikely at the limit dose. The limit dose should be adequate for assessment purposes, and it is usually 2000 mg/kg-bwt. Five or ten birds are tested at the limit dose in addition to a control group. The LD50-slope test is the preferred test when regulatory or other requirements determine that the slope of the dose-response curve and/or the confidence interval is required in addition to an estimate of the LD50. This is a 3- or 4-stage test with 24 or 34 birds in addition to a control group. The LD50-only test is the preferred test when regulatory or other requirements determine that only the median lethal dose is required but neither the slope of the dose response curve or the confidence interval for the LD50 is required. This may be the appropriate test to estimate a percentile of a species sensitivity distribution of LD50s and to provide information for product labelling purposes. This test has two stages, with 14 birds in addition to a control group. Software to be used with TG 223. Click here. Software not part of the Mutual Acceptance of Data.
ISBN:
92-64-26451-5

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Library Catalog Using Articles+ Library Account