Summary:
A new method of measuring diesel-particulate accumulation has been developed that uses electromagnetic energy to interrogate a ceramic filter and to give a real-time measurement of the trapped-soot level. The measurement method is inherently independent of engine-exhaust-gas volumetric flow rates and is relatively insensitive to changes in filter temperature.This paper presents laboratory data, derived from testing of full-scale, wall-flow filter systems, demostrating the viability of the measurement method. The implementation of the measurement method in on-vehicle regeneration system is also discussed
Notes:
Vendor supplied data
Publisher Number:
910324
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account