On-Line Measurement of Diesel Particulate Loading in Ceramic Filters, 1991 AECL Research - Whiteshell Labs
- Format:
- Conference/Event
- Author/Creator:
- Walton, Walton, author.
- Conference Name:
- International Congress & Exposition (1991-02-25 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1991
- Summary:
- A new method of measuring diesel-particulate accumulation has been developed that uses electromagnetic energy to interrogate a ceramic filter and to give a real-time measurement of the trapped-soot level. The measurement method is inherently independent of engine-exhaust-gas volumetric flow rates and is relatively insensitive to changes in filter temperature.This paper presents laboratory data, derived from testing of full-scale, wall-flow filter systems, demostrating the viability of the measurement method. The implementation of the measurement method in on-vehicle regeneration system is also discussed