1 option
Dynamic Fatigue Data for Cordierite Ceramic Wall-Flow Diesel Filters Corning Incorporated Corning, NY
- Format:
- Conference/Event
- Author/Creator:
- Gulati, Suresh T., author.
- Conference Name:
- International Congress & Exposition (1991-02-25 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1991
- Summary:
- The dynamic fatigue data for two different cordierite ceramic wall-flow diesel filter compositions, EX-54 and EX-66, are obtained at 200° and 400°C using the 4-point bend test. These compositions offer larger mean pore size and experience lower pressure drop than the EX-47 composition, and hence are more desirable for certain applications. Their fatigue behavior in the operating temperature range is found to be equivalent or superior to that of EX-47 composition which helps promote filter durability. The fatigue data are used to arrive at a safe allowable stress, which would ensure the required 290K vehicle mile durability. The paper also discusses the impact of mean pore size on high temperature strength and fatigue properties and their effect on filter durability
- Notes:
- Vendor supplied data
- Publisher Number:
- 910135
- Access Restriction:
- Restricted for use by site license