Prediction Method on Effect of Thermal Performance of Heat Exchanger due to Non-uniform Air Flow Distribution Mitsubishi Heavy Industries, Limited Japan

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Kondo, F., author.
Conference Name:
SAE International Congress & Exposition (1985-02-25 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1985
Summary:
The prediction method on flow and thermal performance in the cooling unit of automobile air conditioning systems was investigated. The two- and three-dimensional flow in the model unit based on the actual cooling unit was numerically solved by the modified FLIC (Fluid In Cell) method. The effect of the air flow maldistribution on the thermal performance of the evaporator was predicted by using the air flow distribution calculated about the model unit. Some experiments were performed to confirm the above numerical procedures. It is shown that both predicted results are in good agreement with the measured data