1 option
Design and Performance of a Packaged 60 Kilowatt Cogeneration System
- Format:
- Conference/Event
- Author/Creator:
- Koplow, Michael D., author.
- Conference Name:
- West Coast International Meeting and Exposition (1984-08-06 : San Diego, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1984
- Summary:
- A packaged cogeneration system fueled by natural gas and rated at 60 kW electrical output and 440,000 Btu/hr thermal output was developed using an automotive engine prime mover. Adaptation of the low-cost, compact automotive engine for reliable and continuous operation on natural gas was a major factor in achieving the design and cost goals for a product serving the small-scale cogeneration market. This paper describes the system and discusses the product design rationale and engine development
- Notes:
- Vendor supplied data
- Publisher Number:
- 841016
- Access Restriction:
- Restricted for use by site license