1 option
Fast Start System for a 200-KW Gas Turbine Generator Set
- Format:
- Conference/Event
- Author/Creator:
- Rodgers, Colin, author.
- Conference Name:
- Aerospace Congress & Exposition (1984-10-15 : Long Beach, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1984
- Summary:
- Emergency standby generator systems require rapid start characteristics capable of providing on-line operation within 10 seconds under a wide range of environmental conditions. This paper describes the design and development of a fast start, air impingement system for a 200-kW, single-shaft, gas turbine generator set. The conventional electric start system was replaced by a high pressure, air start system which reduced the total start-to-load time from 21 to 9 seconds
- Notes:
- Vendor supplied data
- Publisher Number:
- 841568
- Access Restriction:
- Restricted for use by site license