Steady-State and Transient A/F Control Requirements for Cold Operation of a 1.6 Liter Engine with Single-Point Fuel Injection Control Systems Dept. Engineering and Research Staff Ford Motor Company
- Format:
- Conference/Event
- Author/Creator:
- Aquino, Charles, author.
- Conference Name:
- SAE International Congress & Exposition (1985-02-25 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1985
- Summary:
- An engine dynamometer test facility-capable of controlling temperatures from 0°F to 150°F was used to investigate A/F control characteristics of a 1.6 liter engine with single point fuel injection. Two types of tests were run. In the first, the effect of induction system temperature on manifold wall wetting and transient A/F control was determined. In the second, a cold start procedure was developed to determine the effect of engine temperature on the percent of fuel which burns by observing exhaust A/F during steady state operation while the engine warms up. It was found that transient A/F control problems due to manifold wall wetting are much greater than steady state problems associated with incomplete fuel burning