Opacity and Photoacoustic Measurements of Diesel Particle Mass Emissions Physics Dept., General Motors Research Labs., Warren, MI

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Roessler, David M., author.
Conference Name:
SAE International Congress & Exposition (1982-02-22 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1982
Summary:
We have compared the capabilities of two optical instruments -- a conventional opacity meter and a photoacoustic device developed in our laboratory -- as tools for measurement of diesel particulate emissions. The devices were tested using emissions from several 5.7 ℓ engines operated at various steady-state conditions of speed and load and also over the Federal Test Procedure driving cycle. The photoacoustic instrument is about 10 times more sensitive than the opacity meter. Further, unlike the opacity meter, its calibration to give mass concentration is independent of particle size variations