My Account Log in

1 option

Measurement of Tube/Tube Support Clearance via Induced Vibration Analysis ANCO Engineers, Incorporated

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Barrett, Don C., author.
Conference Name:
Aerospace Congress & Exposition (1980-10-13 : Los Angeles, California, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1980
Summary:
A number of nuclear power plant steam generators have been troubled with corrosion buildup between the tubes and supporting plates. A vibration type probe which traverses the interior of the tubes during plant shutdown has been developed to inspect the tube and support crevices. The probe incorporates a miniature electric vibrator and accelerometers to induce and measure tube motion at the support plate junctions. Laboratory investigation indicates that clearance gaps ranging from 1 to 30 mils can be accurately and rapidly measured even in the presence of tube misalignment and varied tube support conditions. The probe system is also suited to in-situ measurements of heat exchanger tube vibration characteristics
Notes:
Vendor supplied data
Publisher Number:
801127
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account