Measurement of Tube/Tube Support Clearance via Induced Vibration Analysis ANCO Engineers, Incorporated
- Format:
- Conference/Event
- Author/Creator:
- Barrett, Don C., author.
- Conference Name:
- Aerospace Congress & Exposition (1980-10-13 : Los Angeles, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1980
- Summary:
- A number of nuclear power plant steam generators have been troubled with corrosion buildup between the tubes and supporting plates. A vibration type probe which traverses the interior of the tubes during plant shutdown has been developed to inspect the tube and support crevices. The probe incorporates a miniature electric vibrator and accelerometers to induce and measure tube motion at the support plate junctions. Laboratory investigation indicates that clearance gaps ranging from 1 to 30 mils can be accurately and rapidly measured even in the presence of tube misalignment and varied tube support conditions. The probe system is also suited to in-situ measurements of heat exchanger tube vibration characteristics
- Notes:
- Vendor supplied data
- Publisher Number:
- 801127
- Access Restriction:
- Restricted for use by site license