The Data Acquisition System at the DCIEM Impact Studies Facility Defence and Civil Institute of Environmental Medicine Downsview, Ontario, Canada
- Format:
- Conference/Event
- Author/Creator:
- Bowden, Timothy J., author.
- Conference Name:
- Passenger Car Meeting and Exposition (1981-06-08 : Dearborn, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1981
- Summary:
- The data acquisition system for impact testing at the Defence and Civil Institute of Environmental Medicine (DCIEM) uses a set of 49 Datalab recorders. Each of these recorders converts an analog transient electrical signal into digital form at sampling rate up to 200 kHz and stores 4096 samples for subsequent transfer to a computer. Data processing and plotting of results, including resultants and severity indices, is completed within 40 minutes of a test. The system offers a speed and versatility far superior to alternative systems using analog FM magnetic tape recorders
- Notes:
- Vendor supplied data
- Publisher Number:
- 810812
- Access Restriction:
- Restricted for use by site license