Summary:
The 1980 X-Car engine cooling system is designed to aid in maximizing fuel economy. An electrically driven fan was selected to provide airflow to meet the above objective. Several other design objectives such as light weight and low noise level are also very well satisfied by the electric fan. This paper describes the strategy and techniques used to meet the fuel economy improvement goal while still providing acceptable engine cooling and the airflow required for adequate air conditioning condensing. This strategy consisted of maximizing ram airflow via methods of wind tunnel, flowmeter and on road development. The heat exchangers were then sized to perform adequately with only ram airflow in a road load condition. Finally the additional airflow required at idle and at high heat rejection points was determined. A high peak efficiency fan was selected to provide the airflow needed when operating near its maximum efficiency
Notes:
Vendor supplied data
Publisher Number:
790722
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Library Catalog Using Articles+ Library Account