1 option
Electric Cooling Fan with High Ram Airflow - A Fuel Economy Improvement - (Part One - The Vehicle) (Part Two - The Fan) (Part Three - The Electric Fan Cooling Package Assembly) Chevrolet Motor Div., General Motors Corporation
- Format:
- Conference/Event
- Author/Creator:
- Laise, Terrance D., author.
- Conference Name:
- Passenger Car Meeting and Exposition (1979-06-11 : Dearborn, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1979
- Summary:
- The 1980 X-Car engine cooling system is designed to aid in maximizing fuel economy. An electrically driven fan was selected to provide airflow to meet the above objective. Several other design objectives such as light weight and low noise level are also very well satisfied by the electric fan. This paper describes the strategy and techniques used to meet the fuel economy improvement goal while still providing acceptable engine cooling and the airflow required for adequate air conditioning condensing. This strategy consisted of maximizing ram airflow via methods of wind tunnel, flowmeter and on road development. The heat exchangers were then sized to perform adequately with only ram airflow in a road load condition. Finally the additional airflow required at idle and at high heat rejection points was determined. A high peak efficiency fan was selected to provide the airflow needed when operating near its maximum efficiency
- Notes:
- Vendor supplied data
- Publisher Number:
- 790722
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.