1 option
Trapping Efficiency Depending on Particulate Size
- Format:
- Conference/Event
- Author/Creator:
- Mayer, A., author.
- Conference Name:
- International Congress & Exposition (1996-02-26 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1996
- Summary:
- 1. ABSTRACTThere is growing concern about the risk potential of Diesel particulates. This prompted two Swiss R&D projects focused on the capabilities of different soot trap concepts for filtering finest particulates. Eight different filter media, some in numerous variants, were tested on four different Diesel engines. All traps attained their gravimetric target. However, there are noticeable performance differences for finest particulates at or smaller than 50 nm. Fiber deep filters seem to be noticeably better than other filter types. If the carcinogens are mainly the finest particulates, then this criterion may become important in future trap evaluation
- Notes:
- Vendor supplied data
- Publisher Number:
- 960472
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.