1 option
An Investigation of International Space Station Trace Contaminant Oxidation Catalyst Poisoning TDA Research, Incorporated
- Format:
- Conference/Event
- Author/Creator:
- Wright, John D., author.
- Conference Name:
- International Conference On Environmental Systems (1996-07-08 : Monterey, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1996
- Summary:
- The Trace Contaminant Control System (TCCS) removes most hazardous contaminants from the space station atmosphere using a carbon bed, but some must be destroyed in a high temperature catalytic oxidizer. While the oxidizer is protected from catalyst poisons by the carbon bed, if contaminant loads are greater than anticipated, the catalyst may be exposed to a variety of poisons. Thus, we studied the effect of halocarbons, sulfides and nitrogen compounds on the catalytic activity and the products produced. We found that even if poisoning occurs, the catalyst will recover, and will not produce toxic partial oxidation products
- Notes:
- Vendor supplied data
- Publisher Number:
- 961517
- Access Restriction:
- Restricted for use by site license