My Account Log in

1 option

Measurement of Total Hemispherical Emittance at Cryogenic Temperatures Keio Univ

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Furusawa, Tohru, author.
Conference Name:
International Conference On Environmental Systems (1996-07-08 : Monterey, California, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1996
Summary:
A method for measurement of total hemispherical emittance of metals at cryogenic temperatures is described. The principle of the measurement is based on calorimetric method and total hemispherical emittance as a function of temperature is obtained by measuring the equilibrium temperature of a specimen corresponding to different heat input, which is given to a heater attached to the specimen.Measurements of total hemispherical emittance and specific heat have been carried out on the specimen of lead over a temperature range of 1040 K. In order to verify the measurement method, uncertainty on heat loss is discussed