1 option
Monitoring Moisture and Wear Particles in PAG and POE Synthetic Lubricants for R-134a Compressors Using Portable Oil Analyzer
- Format:
- Conference/Event
- Author/Creator:
- Garvey, Ray, author.
- Conference Name:
- International Fuels and Lubricants Meeting and Exposition (1994-10-17 : Baltimore, Maryland, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1994
- Summary:
- Polyalkalene glycols, or PAG, and polyol esters, or POE, are two synthetic lubricants commonly used in refrigerant compressors. They are both hygroscopic. Moisture which is picked up can lead to chemically weakened load bearing surfaces and to corrosion, thereby accelerating mechanical wear.PAG and POE lubricant samples having from 0.00% to 1.28% water were tested using a portable oil analyzer. Minimum detectibility was found to begin at 0.04% (400 ppm) moisture. Increasing amounts of moisture above this amount yielded proportional output response. Additional samples were contaminated with known concentrations of metal particles representative of common wear debris. Minimum detectability was found to begin at approximately 15 ppm for 4 to 6 micron size iron particles and <100 ppm for 0 to 60 micron size tin particles
- Notes:
- Vendor supplied data
- Publisher Number:
- 942029
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.