Evaluation of 5th Percentile Female Hybrid III Thoracic Biofidelity during Out-of-Position Tests with a Driver Air Bag University of Virginia
- Format:
- Book
- Conference/Event
- Author/Creator:
- Crandall, J.R., author.
- Conference Name:
- International Congress & Exposition (1998-02-23 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource cm
- Place of Publication:
- Warrendale, PA SAE International 1998
- Summary:
- This paper evaluates the biofidelity of the Hybrid III 5th percentile female dummy relative to seven small female cadavers tested as out-of-position drivers in static air bag deployment tests. In the out-of-position tests, the chest was positioned against the air bag module in an effort to recreate a worst-case loading environment for the thorax. Two pre-depowered production air bags and a prototype dual-stage air bag were evaluated. Thoracic accelerometers and chestbands were used to compare chest compression, velocity, acceleration, and Viscous Criteria. A statistical comparison of dummy and cadaver results indicate acceptable biofidelity of the Hybrid III dummy with significant differences observed only in the Viscous Criteria
- Notes:
- Vendor supplied data
- Publisher Number:
- 980636
- Access Restriction:
- Restricted for use by site license