1 option
Flight and Ground Test Data Analysis for the Heat Pipe Performance (HPP) Experiment OAO Corporation
- Format:
- Conference/Event
- Author/Creator:
- Buchko, Matthew T., author.
- Conference Name:
- International Conference On Environmental Systems (1994-06-20 : Friedrichshafen, Germany)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1994
- Summary:
- This paper presents the test results and data correlation for the Heat Pipe Performance Flight Experiment which was a Class D middeck experiment flown aboard the Space Shuttle Columbia (STS-52) in October of 1992. Three categories of heat pipe performance were examined: static mode, operation under applied acceleration, and re-wicking capability. Two aluminum/freon axially grooved heat pipes, ten copper/water axially grooved heat pipes, and four fibrous wick copper/water variable conductance heat pipes were tested. Ground and flight test results for the axially grooved heat pipes are discussed and correlated with analytical models. Correlation of flight test data for cryogenic axially grooved oxygen heat pipes and a description of the Groove Analysis Program (GAP) is also presented
- Notes:
- Vendor supplied data
- Publisher Number:
- 941300
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.