Open-Loop Chestbands for Dynamic Deformation Measurements University of Virginia

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Bass, C. R., author.
Conference Name:
International Congress & Exposition (1998-02-23 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1998
Summary:
Originally designed for measuring closed-loop contours such as those around a human thorax, the External Peripheral Instrument for Deformation Measurement (EPIDM), or chestband, was developed to improve the measurement of dummy and cadaver thoracic response during impact. In the closed-loop configuration, the chestband wraps around on itself forming a closed contour. This study investigates the use of the chestband for dynamic deformation measurements in an open-loop configuration. In the open-loop configuration, the chestband does not generally form a closed contour. This work includes enhanced procedures and algorithms for the calculation of chestband deformation contours including the determination of static and dynamic chestband contours under several boundary conditions. Accurate numerical techniques and chestband gauge calibration procedures were developed to ensure accuracy when integrating curvatures from a single boundary condition on one end of the chestband to the unknown boundary other end of the chestband.The device demonstrated reliability and repeatability in a series of open-loop static and dynamic tests. These tests include a static open loop deformation using a sinusoidal mandrel, a dynamic test using a 127 mm diameter cylindrical impactor, and an S-shaped impactor of approximately 120 mm and 180 mm diameter at each loop. The two dynamic impactors were tested at a low velocity of approximately 4 m/s and a high velocity of approximately 6 m/s. Computer generated contours from these static and dynamic tests were compared to contours determined from high speed video analysis. A high degree of correlation was found between the two sets of contours to support the use of the chestband in an impact environment in an open-loop configuration.Potential areas of application include the measurement of dynamic deformations during automobile toepan intrusion, the measurement of local dynamic deformation of a restraint belt, and the measurement of the dynamic deformation of dash panels under occupant knee/leg impact
Notes:
Vendor supplied data
Publisher Number:
980857
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account