1 option
Condensing Heat Exchanger Microbial Growth and Control Study-Phase II Hamilton Standard Division of United Technologies Corporation
- Format:
- Conference/Event
- Author/Creator:
- Marsh, Robert W., author.
- Conference Name:
- International Conference On Environmental Systems (1993-07-12 : Colorado Springs, Colorado, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1993
- Summary:
- The Space Station Temperature and Humidity Control Condensing Heat Exchangers will be utilized to collect and remove atmospheric water vapor generated by the metabolic and hygienic activity of crew members. The porous hydrophilic coating within the heat exchangers will always be wet. Cabin air will continuously flow through the heat exchangers during system operation which makes them a potential site for microbial colonization.This paper summarizes the findings from an ongoing study which evaluates biofilm formation on wet hydrophilic coated panels compared to panels to which microbial control measures have been applied. The control measures evaluated are an antimicrobial agent within the coating and periodic drying
- Notes:
- Vendor supplied data
- Publisher Number:
- 932107
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.