Dual-Membrane Gas Trap for the Space Station Freedom Internal Thermal Control System AlliedSignal Research and Technology

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Faust, Michael B., author.
Conference Name:
International Conference On Environmental Systems (1993-07-12 : Colorado Springs, Colorado, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1993
Summary:
A gas trap is being developed for use in the internal thermal control system (ITCS) of Space Station Freedom. The function of the gas trap is to remove and vent noncondensed gases (NCG) that may be entrained in the ITCS water loop. Noncondensed gas bubbles in excessive concentrations can cause the performance of the centrifugal pump to degrade, block coolant flow in remote components, and cause inaccuracies in instrumentation readings.A design has been created utilizing polypropylene hydrophobic and nylon hydrophilic membranes. The hydrophobic membrane allows gas transfer from the water/gas mixture across the membrane to ambient, and blocks liquid flow at the expected ITCS pressure levels. The hydrophilic membrane permits ITCS water to flow through the membrane, and blocks noncondensed gas at the expected water pressure differential. The water leaving the hydrophilic membrane is degassed and exits from the gas trap. The gas trap orbital replacement unit (ORU) design weighs 10.5 lb, has a water pressure drop of 2.5 psid at a flow rate of 3000 lb/hr, and will meet water leakage requirements at system pressures of 85 psig. Subscale tests of the final configuration have shown essentially complete removal of air NCG at concentrations up to 10 percent by volume at a 3000-lb/hr water flow rate and up to 20 percent by volume at a 1230-lb/hr water flow rate.This paper describes the pump sensitivity tests, gas trap trade study, membrane selection process, development testing, and evolution of the gas trap membrane module. The final gas trap design is nearing completion, and the latest test results are presented in this paper
Notes:
Vendor supplied data
Publisher Number:
932162
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account