Diesel Fuel Ignition Quality Measurement by a Constant Volume Combustion Test Esso Research Centre
- Format:
- Conference/Event
- Author/Creator:
- Datschefski, Gunter, author.
- Conference Name:
- International Fuels and Lubricants Meeting and Exposition (1993-10-18 : Philadelphia, Pennsylvania, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1993
- Summary:
- A new technique for measuring ignition quality of diesel fuels has been evaluated. Primarily a constant volume combustion apparatus, the Diesel Fuel Ignition Analyser (DFIA) provides a direct output of ignition delay. Microprocessor control and semi-automatic operation ensure rapid determinations. Tests were performed to find the operating conditions giving the best results in terms of various performance indicators, settling upon 450°C/20bar for combustion air preheat and pressure.A preliminary correlation model based on ignition delay predicted D613 Cetane Number with ± 1.3CN at 95% confidence. More results are required to improve this correlation and define statistical precision of the method
- Notes:
- Vendor supplied data
- Publisher Number:
- 932743
- Access Restriction:
- Restricted for use by site license