1 option
Refrigerants CFC-12/HFC-134a and Submarine Atmosphere Control Carderock Division - Naval Surface Warfare Center
- Format:
- Conference/Event
- Author/Creator:
- McCarrick, Alan D., author.
- Conference Name:
- International Conference On Environmental Systems (1993-07-12 : Colorado Springs, Colorado, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1993
- Summary:
- Alternate refrigerant HFC-134a has been found to be substantially more reactive than CFC-12 in the US Navy submarine catalytic burner. The burner operates at 316°C and uses a manganese dioxide/copper monoxide catalyst, Hopcalite. The reaction of HFC-134a produced hazardous quantities of HF in the outlet air in excess of the established submarine exposure limits. No other hazardous products, such as carbonyl fluoride, were detected
- Notes:
- Vendor supplied data
- Publisher Number:
- 932286
- Access Restriction:
- Restricted for use by site license