My Account Log in

1 option

"SODART" Telescope Silicon Detector Cooling System (Thermal Test Results of the Scale-Down Model) The Div. of the Scientific Research Institute of Electromechanics

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Abrosimov, Aleksander, author.
Conference Name:
International Conference On Environmental Systems (1992-07-12 : Seattle, Washington, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1992
Summary:
.The onboard "SODART" telescope silicon detector cooling system of the "Spectrum-X-Gamma" observatory, which is designed for the space objects X-ray radiation study, is described. The scale-down model of the passive cooling system description and thermal vacuum test results of this model are given. In the real cooling system the minimal detector temperature at 300 mW heat release is expected about 107 K.
Notes:
Vendor supplied data
Publisher Number:
921365
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.