SP-100 Initial Startup and Restart Control Strategy General Electric Company

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Halfen, Frank J., author.
Conference Name:
27th Intersociety Energy Conversion Engineering Conference (1992) (1992-08-03 : San Diego, California, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1992
Summary:
Recent Generic Flight System (GFS) updates have necessitated revisions in the initial startup and restart control strategies. The design changes that have had the most impact on the control strategies are the addition of the Auxiliary Cooling and Thaw (ACT) system for preheating the lithium filled components, changes in the reactivity worths of the reflectors and safety-rods such that initial cold criticality is achieved with only a small amount of reflector movement following the withdrawal of the safety-rods, and the removal of the scram function from the reflectors.Revised control and operating strategies have been developed and tested using the SP-100 dynamic simulation model, ARIES-GFS. The change in the total reactivity worths of the reflectors and safety-rods has eliminated the need for the use of fast and slow reflector drive speeds during the initial on-orbit approach to criticality. The relatively fast removal of the safety-rods results in a near-critical condition so that the use of slow moving (single speed) reflector drives does not add significant time to achieve full power for the initial startup. The use of the ACT system (with its NaK trace-lines for preheating and auxiliary cooling) affects the main Thermoelectic Electro-Magnetic (TEM) pump startup and the time after a shutdown before freezing occurs in the main heat transfer systems. The control strategies developed provide a simpler and more robust control system that fully meets GFS performance requirements, compared to that presented at the System Design Review
Notes:
Vendor supplied data
Publisher Number:
929231
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account