Two-Phase Flow and Pressure Drop in Flow Passages of Compact Heat Exchangers Argonne National Lab
- Format:
- Conference/Event
- Author/Creator:
- Wambsganss, M.W., author.
- Conference Name:
- International Congress & Exposition (1992-02-24 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1992
- Summary:
- Two-phase flow experiments were performed with air/water mixtures in a small rectangular channel measuring 9.52 x 1.59 mm (aspect ratio equal to 6), for application to compact heat exchangers. Pressure drop and flow pattern definition data were obtained over a large range of mass qualities (0.0002 to 1) and, in the case of flow pattern data, a large range of mass fluxes (50 to 2,000 kg/m2s). A flow pattern map, based on visual observations and photographs of the flow patterns, is presented and compared with a map developed for a rectangular channel of the same aspect ratio but with dimensions twice those of the test channel, and with a map developed for a circular tube with the same hydraulic diameter of 3 mm. Pressure drop data are presented as a function of both mass quality and Martinelli parameter and are compared with state-of-the-art correlations and a modified Chisholm correlation