My Account Log in

1 option

Adaptation of Sub-cool Condenser for an Air Conditioning System Employing an Internal Heat Exchanger Subros Limited

SAE Technical Papers (1906-current) Available online

View online
Format:
Book
Conference/Event
Author/Creator:
Suman, Saurabh, author.
Contributor:
Kushwah, Yogendra Singh
maske, Suraj
Conference Name:
Thermal Management Systems Conference 2020 (2020-08-26 : Online, India)
Language:
English
Physical Description:
1 online resource cm
Place of Publication:
Warrendale, PA SAE International 2020
Summary:
Recently, the use of air conditioning systems is growing rapidly due to increasing global temperatures. Considering enormous growth in the application of the air conditioning system, there is an urgent need to improve design, performance, and efficiency thereof. For example, the air conditioning systems that are being used these days are required to provide improved efficiency per unit of power consumed, and they are also required to have a smaller form factor as compared to conventional air conditioning systems. Therefore, a lot of modern air conditioning systems employ components such as internal heat exchanger, thermal expansion valves and forth to improve their performance while having a small form factor. Adaptation of internal heat exchanger provides additional heat transfer between the high temperature sub-cooled liquid from the condenser and super-heated cold vapor from the evaporator, which can reduce the inlet vapor quality to the evaporator and potentially increase the system heat capacity and coefficient of performance.In this study a condenser is adapted to be used for an air conditioning system employing an internal heat exchanger. Wherein the condenser sub-cool area is in a optimized range with respect to frontal condenser area. Also the effect of IHX on the sub-cooling part of the condenser has been analyzed and optimized accordingly as per the system requirement. R134a has been used as refrigerant for the analysis. The sizing of sub-cool portion of condenser inline of internal heat exchanger capacity for a given system results up to 10% improvement in the coefficient of performance of AC system
Notes:
Vendor supplied data
Publisher Number:
2020-28-0026
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account