Responses of the THOR in Oblique Sled Impacts: Focus on Chest Deflection Ford Motor Company, Limited

SAE Technical Papers (1906-current) Available online

View online
Format:
Book
Conference/Event
Author/Creator:
El-Jawahri, Raed E., author.
Contributor:
Gao, Zhenyan
Jaradi, Dean
McCoy, Robert W.
Ruthinowski, Rich
Siasoco, Kevin
Conference Name:
WCX SAE World Congress Experience (2020-04-21 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource cm
Place of Publication:
Warrendale, PA SAE International 2020
Summary:
The National Highway Traffic Safety Administration (NHTSA) published a Request for Comments (RFC) on proposed changes to the New Car Assessment Program (NCAP) in December of 2015. One potential change was the introduction of a frontal Oblique Impact (OI) crash test. The Test device for Human Occupant Restraint (THOR) in the front left seat was used in the proposed OI test.In the current study, eleven oblique sled impact tests were conducted. The environment was representative of a generic mid-sized sedan. The buck was mounted on a rigid plate that allowed the pre-test rotation of the buck relative to the sled axis. A generic mid-sized OI pulse was used. The pulse was applied in the longitudinal direction of the sled. The THOR was seated in the driver seat and was restrained with a 3-point belt, a driver airbag (DAB) and a knee airbag (KAB). The belt had a 4-2.5 kN digressive shoulder load limit (LL), a retractor pre-tensioner (RPT) and an anchor pre-tensioner (APT). Out of the four IR-TRACC locations, the upper right (UR) yielded the maximum chest deflection in all tests. Responses of the other body regions were also reported. Neither the presence of side structure nor the position of the D-ring had significant effect on the THOR responses.In addition, four tests with the THOR and two tests with the Hybrid III 50th male (HIII-50M) dummies seated on a rigid seat were conducted. The two dummies were restrained with the same 3-point belt used in the sled tests. In those tests, no pulse was applied and only the PTs were fired. Like the sled tests, the APT was fired 5 ms after the RPT. In the THOR tests, the UR yielded the maximum chest deflection out of the four locations. The average chest deflection of the four tests was 16.8 mm. Whereas, the average of the chest pot deflection of the HIII-50M was 10.9 mm
Notes:
Vendor supplied data
Publisher Number:
2020-01-0522
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account