My Account Log in

1 option

On Soot Sampling: Considerations when Sampling for TEM Imaging and Differential Mobility Spectrometer Norwegian Univ of Science and Technology

SAE Technical Papers (1906-current) Available online

View online
Format:
Book
Conference/Event
Author/Creator:
Emberson, David Robert, author.
Contributor:
Lovas, Terese
Rohani, Behzad
Sæterli PhD, Ragnhild
Wang PhD, Liang
Conference Name:
14th International Conference on Engines & Vehicles (2019-09-15 : Capri, Italy)
Language:
English
Physical Description:
1 online resource cm
Place of Publication:
Warrendale, PA SAE International 2019
Summary:
Particulate matter (PM) has been sampled from a compression ignition engine using a differential mobility spectrometer (Cambustion DMS 500) and for imaging in a transmission electron microscope (TEM) with the aim of coupling these two measuring techniques. A known issue when coupling these two methods is that a devise like the DMS samples all PM, and the TEM only soot. To help resolve this issue, a thermal denuder was designed and built to remove all volatile organic compounds (VOC) from the sample prior to entering the DMS. For TEM imaging, soot was either collected directly onto a TEM grid using the thermophoretic effect or collected onto quartz filters with the soot then transferred onto the TEM grids. The direct to grid technique did not work after the denuder due to the gas temperature being too low for the thermophoretic effect; hence the reason to collect some soot using the quartz filters. Soot was removed from the filters using an ethanol wash/sonication technique. Morphology; diameter of gyration, projected area, primary particle size and fractal dimension have been compared between the two TEM sampling techniques, with or without the denuder. Denuder effectiveness has been assessed using TGA analysis of sampled soot. Issues concerning the sampling process itself are outlined. A comparison between the TEM and the DMS results is conducted with the discrepancies between them discussed. Direct and filter sampling gave similar results as long as the sonication process and grid prep is done properly, otherwise the filter wash technique results in a number of clusters of agglomerates which distorts the post processing and morphological data
Notes:
Vendor supplied data
Publisher Number:
2019-24-0159
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides