My Account Log in

1 option

Variation in System Performance while Sorting DEF Heating Hardware Options PACCAR Technical Center

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Vermiglio, Vermiglio, author.
Contributor:
Chin, Anthony
Erickson, Darren
Gilliam, Kyle
Leonard, Treaver
Conference Name:
International Powertrains, Fuels & Lubricants Meeting (2018-09-17 : Heidelberg, Germany)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2018
Summary:
AbstractThe desire to reduce NOx at low ambient temperatures drives the use of heating methods to make DEF available by thawing the solution in the tank. Methods to validate modelling used to design hardware options require testing to gauge the accuracy of the prediction. Using a climatic chassis dynamometer (CCD) to demonstrate the guidance procedure set by the Environmental Protection Agency (EPA) is expensive and time consuming. A method of utilizing a flow controlled cooling supply combined with a standard cold chamber is described as a precursor to running the demonstration in the CCD. Testing multiple quantities of design iterations produced unexpected variation in the results. The sources of the variation and modifications taken to minimize them are discussed and presented. Test to test control of coolant flow, coolant temperature, and specific chamber temperature inconsistencies were found to be critically important to a successful effort. Several design iterations were compared with varying degrees of success. The method was modified as variation between tanks of the same design was noted. System description details as well as modifications to the process are discussed. A design that maximizes heat transfer to the DEF pick up area while providing enough heat to melt the remainder of the volume was found to clearly out-perform the others. Test apparatus details are described. The DEF heating loop system is exposed to varying temperatures and flows in the truck. Selection of a representative coolant flow and temperature is discussed. The EPA certification test method options are referenced. Control parameters are defined with the intent of demonstrating a test practice that minimizes CCD time and ultimately accurately predicts hardware performance on the certification test
Notes:
Vendor supplied data
Publisher Number:
2018-01-1813
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Library Catalog Using Articles+ Library Account