A New Validation of Spray Penetration Models for Modern Heavy Duty Diesel Fuel Injectors Caterpillar Incorporated
- Format:
- Conference/Event
- Author/Creator:
- Fitzgerald, Fitzgerald, author.
- Conference Name:
- WCX 17: SAE World Congress Experience (2017-04-04 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2017
- Summary:
- AbstractThe performance of five positive k-factor injector tips has been assessed in this work by analyzing a comprehensive set of injected mass, momentum, and spray measurements. Using high speed shadowgraphs of the injected diesel plumes, the sensitivities of measured vapor penetration and dispersion to injection pressure (100-250MPa) and ambient density (20-52 kg/m3) have been compared with the Naber-Siebers empirical spray model to gain understanding of second order effects of orifice diameter. Varying in size from 137 to 353μm, the orifice diameters and corresponding injector tips are appropriate for a relatively wide range of engine cylinder sizes (from 0.5 to 5L). In this regime, decreasing the orifice exit diameter was found to reduce spray penetration sensitivity to differential injection pressure. The cone angle and k-factored orifice exit diameter were found to be uncorrelated.Measurements of injector rate shape, orifice discharge coefficients, spray cone angle, and vapor penetration have also been reconciled with one-dimensional transient computational simulations (Musculus and Kattke) to assess fuel injector tip performance and to evaluate predictive capability. A constant cone angle offset (id est reduction) of 2°, applied to all data is required to reconcile measured and simulated spray vapor penetration. A judicious choice of time after injection to determine cone angle is necessary to distinguish effects of ambient density for all injectors considered in this work. Over a wide range of ambient conditions, vapor penetration measurements agree with simulated values to within 0.6% mean error, bolstering confidence in the model, particularly for larger orifice diameters. The measurements in this work constitute a crucial data set for understanding the performance of heavy-duty diesel injectors and for validating spray models at relevant conditions
- Notes:
- Vendor supplied data
- Publisher Number:
- 2017-01-0826
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.