Summary:
AbstractAn online fault detection and isolation (FDI) method for several common sensor faults and even demagnetization of PMSM is proposed by combining model-based and signal analysis technology. To begin with, the field reconstruction method (FRM) of PMSM is employed to obtain the flux residuals which are used as the criterion of fault detection. Then, the flux residuals are transformed by multi sequence harmonic synchronous rotating transformation and inputted into low pass filters (LPFs) in order to obtain the DC components. Last, offset and gain faults of the two phase current sensors, offset fault of the rotor angle sensor and permanent magnet (PM) demagnetization can be isolated by comparing the DC components and preset thresholds. The detection and isolation strategy of PMSM is validated by motor controller hardware in motor bench tests
Notes:
Vendor supplied data
Publisher Number:
2018-01-0451
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account