Particulate Filter Soot Load Measurements using Radio Frequency Sensors and Potential for Improved Filter Management CTS Corporation Boston Innovation Office

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Ragaller, Ragaller, author.
Contributor:
Bromberg, L. (Leslie)
Gunasekaran, Natarajan
Sappok, Alexander
Warkins, Jason
Wilhelm, Ryan
Conference Name:
SAE 2016 World Congress and Exhibition (2016-04-12 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2016
Summary:
AbstractEfficient aftertreatment management requires accurate sensing of both particulate filter soot and ash levels for optimized feedback control. Currently a combination of pressure drop measurements and predictive models are used to indirectly estimate the loading state of the filter. Accurate determination of filter soot loading levels is challenging under certain operating conditions, particularly following partial regeneration events and at low flow rate (idle) conditions. This work applied radio frequency (RF)-based sensors to provide a direct measure of the particulate filter soot levels in situ. Direct measurements of the filter loading state enable advanced feedback controls to optimize the combined engine and aftertreatment system for improved DPF management. This study instrumented several cordierite and aluminum titanate diesel particulate filters with RF sensors. The systems were tested on a range of light- and heavy-duty applications, which included on- and off-road engines. RF sensor accuracy was evaluated relative to a gravimetric standard over a range of soot loading and regeneration conditions, which included partial regenerations and drop-to-idle events. The results were compared to pressure- and model-based estimates of the filter loading state, and indicate considerable potential to enable an adaptive feedback control system capable of directly responding to the filter loading state even under relatively severe operating conditions. Direct feedback control based on in situ measurements of filter soot levels over a broad range of operating conditions may allow for the development of filter management strategies to improve filter durability and reduce engine fuel consumption relative to current pressure-drop and model based approaches
Notes:
Vendor supplied data
Publisher Number:
2016-01-0943
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account