My Account Log in

1 option

Research on the Application of Micro-Channel Evaporator in R134a Roof-Top Bus Air Conditioner Shanghai Jiaotong University

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Wang, Wang, author.
Contributor:
Chen, Jiangping
Liu, Cichong
Conference Name:
WCX 17: SAE World Congress Experience (2017-04-04 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2017
Summary:
AbstractThis study investigates the cycle performance and potential advantages of the replacement of fin-and-tube evaporator with parallel flow micro-channel evaporator, in R134a roof-top bus air conditioner (AC) system. The heat exchangers for bus AC system are featured by a stringent space height limitation. The configuration of inclined four piece or six piece micro-channel evaporators was proposed to satisfy this space requirement, instead of original two piece fin-and-tube evaporators. Additionally, the individual superheat control method with thermostatic expansive valve (TXV) in each evaporator was adopted to improve refrigerant distribution. Three kinds of micro-channel evaporators were designed and equipped in an 8-m roof-top bus AC system. Except the replacement of evaporators, TXV and connecting pipes, other cycle components were kept same. Comparison experiments were carried out to evaluate the cycle performance with micro-channel evaporator configuration in psychometric calorimeter test facility at rated cooling condition. Experiment results, including R134a refrigerant charge, superheat performance, cooling capacity and system coefficient of performance (COP) were compared between micro-channel evaporator system and fin-and-tube evaporator system. Results show that individual superheat control method improved the superheat distribution uniformity among multiple evaporators, and enhanced the system cooling capacity. Besides, the optimum micro-channel evaporator configuration achieved equal cooling capacity and COP with fin-and-tube evaporators. Furthermore, potential advantages including refrigerant charge reduction, cost saving, system mass reduction, and compact installation were also discussed for the application of micro-channel evaporator in roof-top bus AC system
Notes:
Vendor supplied data
Publisher Number:
2017-01-0161
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account