My Account Log in

1 option

Uncertainties in Emissions Measurements in a Partial Flow Sampling System The Pennsylvania State University

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Mishra, Mishra, author.
Contributor:
Iyer, Suresh
Klinikowski, David
Conference Name:
Symposium on International Automotive Technology 2015 (2015-01-21 : Pune, India)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2015
Summary:
AbstractThis paper investigates experimental uncertainties associated with gaseous and particulate emissions measurements in a partial flow emissions sampling system developed and built at the Larson Transportation Institute of the Pennsylvania State University. A small fraction of the tail pipe exhaust is diluted with dilution air and passed through a cyclone to eliminate particles bigger than 2.5 microns. The diluted exhaust is then passed through a 47 mm Teflon filter for gravimetric measurement of Particulate Matter (PM). Mass flow controllers operating at 5Hz are used to control the flow rates of dilution air, diluted exhaust, and proportional flow of diluted exhaust into a Tedlar bag. An ultrasonic flow meter is used to measure flow rate of tail pipe exhaust. At the end of a test, the concentration of gaseous emissions in the bag, namely CO2, CO, HC, and NOx are measured using a bag emissions analyzer. The mass of gaseous and PM emissions in the tail pipe exhaust for the duration of a test are calculated using the measured gas concentrations in the bag and weight gain of the filter respectively. An uncertainty analysis on the results from an actual test using this system is presented. The propagation of uncertainties in the subsystems used for gas concentration measurements, filter weight determination, and flow rate measurements are used to determine the uncertainties in the results, using the Root Sum Square (RSS) method. The measurement uncertainties from this partial sampling system are then compared to the measurement uncertainties from a full flow dilution tunnel equipped with emissions analyzers for the same test, when both systems are drawing samples simultaneously
Notes:
Vendor supplied data
Publisher Number:
2015-26-0096
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account