Ignition Quality Tester (IQT) Precision Improvements from Using the Totally Automated Laboratory Model (TALM) Technology: Technology Update, Part-2: Mini Inter-Laboratory Study Using the IQT-TALM Advanced Engine Technology, Limited

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Ramadan, Ramadan, author.
Contributor:
Larocque, Jim
Ménard, Luc
Webster, Charlie
Webster, Gary
Wilcox, Aaron
Conference Name:
SAE 2015 World Congress & Exhibition (2015-04-21 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2015
Summary:
AbstractThis paper presents the results of a mini Inter-Laboratory Study (mILS) that is a continuation of earlier work, published in SAE paper number 2014-01-0179 [1]. This work was aimed to improve the capability, precision, and durability of the Ignition Quality Tester (IQT) and ASTM D6890 [2]/EN15195 [3] Test Methods. The mILS was performed to determine how much the TALM IQT Precision Package would improve the precision of four IQTs, relative to a larger number of IQTs participating in two separate Fuel Exchange Programs (FEPs). Two of the IQTs were located at AET and the other two were located at two different external laboratories. All four IQTs were equipped with the TALM Precision Package. Nine fuel samples from the two FEPs with reference DCN values from 33 to 82 were selected for testing. The parameters investigated were: 1) The difference between the average DCN values of the fuel samples and their reference values. 2) The difference between the average standard deviation of DCN values of the fuel samples and their reference values. 3) Effect of mILS results on D6890 method reproducibility and comparison with other Cetane standard test methods. An overall improvement of 63% in the average standard deviation of DCN values was found relative to the reference values reported in the ASTM NEG and the EI CS FEPs. When the mILS results were compared with the average standard deviation of CN reference values reported in the same FEP, the overall improvement was 73%. Over the DCN range of 33 to 70, the mILS results indicate a 53% to 71% improvement in reproducibility compared to the reproducibility published in EN 15195-14 [4]. These results provide an indication of how the addition of the TALM Precision Package to an IQT can markedly improve the precision of the IQT
Notes:
Vendor supplied data
Publisher Number:
2015-01-0805
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.