1 option
Transient Modeling and Validation of an Automotive Secondary Loop Air-Conditioning System University Of Maryland School of Engineering
- Format:
- Conference/Event
- Author/Creator:
- Ling, Ling, author.
- Conference Name:
- SAE 2014 World Congress & Exhibition (2014-04-08 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2014
- Summary:
- AbstractAs a potential replacement to traditional automotive R134a direct expansion (DX) systems, a secondary-loop system allows for the usage of flammable but low-GWP refrigerants such as propane (R290). However, as the secondary-loop system has an additional layer of thermal resistance, the cycle's transient behavior and cabin thermal comfort during pull-down and various driving cycles may be different from traditional DX systems. This paper presents a Modelica-based model to simulate both steady-state and transient operation of automotive secondary-loop systems. The model includes a lumped cabin component and a secondary-loop automotive air-conditioning system component. The air-conditioning system component consists of a condenser, a compressor, an expansion device, a coolant plate type heat exchanger, a coolant to air heat exchanger and a coolant pump. The developed model was validated against both steady-state and transient experimental data for an R290 secondary-loop system. The steady-state comparison demonstrates a 7.5% deviation of air-side COP compared to the experimental data. The (transient) pull-down performance comparison shows maximum of 2.4% and 1.8% deviations of accumulated compressor power and accumulated capacity compared to the experimental data, respectively. The cabin temperature profile predicted by the model during the pull-down condition is within 1K of experimental data. Finally the validated model was used to study the effects of coolant charge amount and glycol concentration on the cabin thermal comfort. It was concluded that the charge variation of up to 2 liters will not significantly affect the thermal comfort, while a less than 30% glycol concentration is preferred
- Notes:
- Vendor supplied data
- Publisher Number:
- 2014-01-0647
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.