1 option
Density and Temperature Gaging of Supercritical Hydrogen and Oxygen for the Apollo Fuel Cells
- Format:
- Conference/Event
- Author/Creator:
- Cohn, I. H., author.
- Conference Name:
- SAE World Congress & Exhibition (1964-01-01 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1964
- Summary:
- The densities of supercritical hydrogen and oxygen are gaged by capacitance sensors -- concentric aluminum tubes which are mounted across the diameter of the spherical tanks. The capacitance of the sensor is a function of fluid density as shown in the Clausius-Mossotti (C-M) relationship. An all-electronic signal conditioner converts the capacitance into a d-c signal output, linearly proportional to the fluid mass. Corrections for the nonlinearity of the C-M equation and for the effects of temperature on the sensors are made by means of diode networks. A platinum resistance temperature sensor is mounted on each sensor and is used with another signal conditioner to provide a d-c signal as a function of fluid temperature
- Notes:
- Vendor supplied data
- Publisher Number:
- 640233
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.