My Account Log in

1 option

Time-Temperature Effect on Jet Engine Thermocouple Accuracy and Reliability

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Clark, Robert B., author.
Conference Name:
National Aeronautic Meeting
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1962
Summary:
Although jet engine thermocouples have been improved considerably over the past 15 years, some research is required into their accuracy and reliability to the extent of mechanical breakdown. The temperature versus time test program discussed here investigates this problem, using two noble metal thermocouple and three sheath materials. The results indicate that accuracy and reliability are questionable after 2300 hr at 1200 F (less at higher temperature) and that more efficient calibration methods need to be adopted. Life limitations due to oxidation and sulfur deterioration of the metals tested are given
Notes:
Vendor supplied data
Publisher Number:
620411
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.