O-Ring Permeation Measurements for Selected Pressures and Gland Designs Columbus Laboratories, Battelle Memorial Institute

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Baum, J. V., author.
Conference Name:
Aerospace Systems Conference and Engineering Display (1967-06-27 : Los Angeles, California, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1967
Summary:
Measurements were made of helium permeation rates for O-rings subjected to helium pressure on one side and vacuum on the other. Helium pressures up to 1000 psi were used in the investigation. Gland designs included grooves for O-ring squeezes from 25 to 75 percent, dual O-ring grooves, and two tongue-and-groove configurations.Calculations were made of the expected permeation rates based on material permeability data. The results of this study indicate that dual O-rings and close-fitting tongue-and-groove designs provide permeation rates that are lower than the rates that are calculated by conventional methods
Notes:
Vendor supplied data
Publisher Number:
670565
Access Restriction:
Restricted for use by site license