O-Ring Permeation Measurements for Selected Pressures and Gland Designs Columbus Laboratories, Battelle Memorial Institute
- Format:
- Conference/Event
- Author/Creator:
- Baum, J. V., author.
- Conference Name:
- Aerospace Systems Conference and Engineering Display (1967-06-27 : Los Angeles, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 1967
- Summary:
- Measurements were made of helium permeation rates for O-rings subjected to helium pressure on one side and vacuum on the other. Helium pressures up to 1000 psi were used in the investigation. Gland designs included grooves for O-ring squeezes from 25 to 75 percent, dual O-ring grooves, and two tongue-and-groove configurations.Calculations were made of the expected permeation rates based on material permeability data. The results of this study indicate that dual O-rings and close-fitting tongue-and-groove designs provide permeation rates that are lower than the rates that are calculated by conventional methods
- Notes:
- Vendor supplied data
- Publisher Number:
- 670565
- Access Restriction:
- Restricted for use by site license