CFD Investigation on the Air Ventilation Characteristics in the U.S. Airlock: International Space Station Flight 7A Configuration

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Lin, Chao-Hsin, author.
Conference Name:
International Conference On Environmental Systems (2002-07-15 : San Antonio, Texas, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2002
Summary:
The objectives of this investigation were to verify the air ventilation characteristics of the U. S. Airlock and to ensure the adequacy of inter-module ventilation (IMV) of the International Space Station (ISS) Flight 7A configuration. There are three operating modes for the air ventilation in the U. S. Airlock: (1) Open Hatch configuration, (2) Closed Hatch configuration and (3) Housekeeping mode. In this study, computational fluid dynamics (CFD) models with the geometrical details representing each mode of the Airlock's operation was built. Proper airflow boundary conditions that represent the operation of the Airlock's Common Cabin Air Assembly (CCAA) and the inter-module ventilation were imposed for the subsequent CFD simulations. Based on the results obtained in this study, the performance of the Airlock ventilation system is marginally acceptable at CCAA fan running at 3600 rpm for both Open Hatch and Closed Hatch operations. In the Housekeeping mode, within the Airlock, most of the air velocity magnitude is below 7 ft/minutes This indicated that part of the air entering from the U. S. Node 1 is trapped inside of the Airlock. For the Open Hatch case, the majority of the airflow entering the Airlock comes from Node 1 through the hatch and the rest (approximately 35%) is pulled into the Airlock through the IMV jumper duct. In examining the overall ventilation performance of the ISS Flight 7A configuration, air circulation in the Node 1 is improved from the previous ISS flights. For the U. S. Laboratory module, its air ventilation effectiveness is neither improved nor deteriorated, as indicated from the CFD results
Notes:
Vendor supplied data
Publisher Number:
2002-01-2342
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account