1 option
Frequency Content Analysis and Filter Class Selection for the Small Female Instrumented Upper Extremity Virginia Tech, Impact Biomechanics Laboratory
- Format:
- Conference/Event
- Author/Creator:
- Stitzel, Joel, author.
- Conference Name:
- SAE 2002 World Congress & Exhibition (2002-03-04 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2002
- Summary:
- Although filter class specifications have been defined for most anthropomorphic test devices, no recommendation exists for the instrumented upper extremity. A three-part study was performed to determine the best channel filter class (CFC) to use for the instrumented upper extremity. By analyzing frequency content of signals from accelerometers and load cells, filtering data through three of the four possible CFC's to compare effects on the signals, and performing an injury comparison between cadaver data and the filtered load cell data, CFC 600 was chosen and recommended as the optimum filter class to use for upper extremity testing
- Notes:
- Vendor supplied data
- Publisher Number:
- 2002-01-0806
- Access Restriction:
- Restricted for use by site license