Evaluation of Two Soil Moisture Sensor Designs for Spaceflight Applications Dynamac Corporation, Kennedy Space Center
- Format:
- Conference/Event
- Author/Creator:
- Norikane, Joey H., author.
- Conference Name:
- International Conference On Environmental Systems (2002-07-15 : San Antonio, Texas, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2002
- Summary:
- A study was conducted evaluating the Temperature and Moisture Acquisition System (TMAS; Orbital Technologies, Madison, WI) and the Specific Heat Sensor (Thermal Logic, Pullman, WA) for root zone moisture level monitoring. Each design used a heat pulse and measured the transient temperature response to determine soil moisture changes. The sensors were placed in a polycarbonate compartment filled with oven-dried 1-2 mm Turface. Data was collected from the dry media, then the media was saturated with water and evaporation was monitored using the sensors and a digital balance. Generally, the TMAS sensors tended to over-estimate, while the Thermal Logic sensors under-estimated changes in soil moisture
- Notes:
- Vendor supplied data
- Publisher Number:
- 2002-01-2385
- Access Restriction:
- Restricted for use by site license