My Account Log in

1 option

Capillary Limit in a Loop Heat Pipe with Dual Evaporators NASA/Goddard Space Flight Center

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Ku, Jentung, author.
Conference Name:
International Conference On Environmental Systems (2002-07-15 : San Antonio, Texas, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2002
Summary:
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration. Furthermore, this process can be repeated with a modest increase in the heat load each time the capillary limit is exceeded until the evaporator temperature exceeds the maximum allowable value. When the heat load is applied to only one of the evaporators, the capillary limit can be identified by a rapid increase in the operating temperature and in the temperature difference between the evaporator and the CC. However, it is more difficult to identify when the capillary limit is exceeded if the heat load is applied to both evaporators. In all cases, the loop can recover by reducing the heat load to the loop
Notes:
Vendor supplied data
Publisher Number:
2002-01-2503
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account