LDA Investigation on Valve - Wall and Valve - Valve Flow Interaction in High-Performance 4-Valve I.C.E. University of Calabria (Italy)

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Bova, Sergio, author.
Conference Name:
SAE 2001 World Congress (2001-03-05 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2001
Summary:
The fluid dynamic efficiency of two different four-valve high-performance engine heads has been compared both in terms of global mass flow rate and in terms of local velocity distribution around the valve curtain, by means of LDA measurements. The two engine heads have the same bore and valve diameters, but a slightly different valve position and valve stem inclination. Results clearly show that valve-wall distance is a critical factor for head permeability and that even marginal variations in valve position and inclination lead to appreciable differences in flow pattern and total flow rate
Notes:
Vendor supplied data
Publisher Number:
2001-01-1309
Access Restriction:
Restricted for use by site license