1 option
A Cooling System for the EAPU Shuttle Upgrade Hamilton Sundstrand Space Systems international, Incorporated
- Format:
- Conference/Event
- Author/Creator:
- Tongue, Stephen, author.
- Conference Name:
- 31st International Conference On Environmental Systems (2001-07-09 : Orlando, Florida, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2001
- Summary:
- The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine-powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges, most notably the new requirement for moderate temperature control of high-power electronics at 132 °F (55.6 °C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management
- Notes:
- Vendor supplied data
- Publisher Number:
- 2001-01-2152
- Access Restriction:
- Restricted for use by site license