International Space Station United States Oxygen Generator Development Testing
- Format:
- Conference/Event
- Author/Creator:
- Erickson, Robert J., author.
- Conference Name:
- International Conference On Environmental Systems (2000-07-10 : Toulouse, France)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2000
- Summary:
- A life test of a liquid anode feed oxygen generator assembly (OGA) using SPE® (United Technologies Corporation, Hamilton Sundstrand Division) membrane technology was terminated in June of 1999. In the total 15,658 hours of operation at MSFC since delivery in 1995, the OGA has produced 2,103 kilograms (kg) (4,632 pounds mass (lbm)) of oxygen, and 263 kg (579 lbm) of hydrogen. Evaluation of cell stack characteristics and oxygen and hydrogen hydrophilic/hydrophobic membrane separators will be discussed
- Notes:
- Vendor supplied data
- Publisher Number:
- 2000-01-2351
- Access Restriction:
- Restricted for use by site license