1 option
Exhaust Heat Exchange Coefficient in a Pipe of an Internal Combustion Engine: EGR Cooler and Passenger Compartment Heating Applications VALEO Engine Cooling
- Format:
- Book
- Conference/Event
- Author/Creator:
- AP, Ngy Srun, author.
- Conference Name:
- SAE 2000 World Congress (2000-03-06 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource cm
- Place of Publication:
- Warrendale, PA SAE International 2000
- Summary:
- This study shows the measurement and calculation of exhaust heat exchange coefficient in a pipe of internal combustion engine. A specific exhaust-air heat exchanger has been installed on the exhaust line of engine. The Nusselt-Reynolds correlation has been developed and compared to the steady state conditions. The Convective Augmentation Factor (CAF) is approximately 2 at low Reynolds number and 1 at high Reynolds number. The EGR cooler and the exhaust-coolant heat exchanger for improving the passenger compartment heating have been shown
- Notes:
- Vendor supplied data
- Publisher Number:
- 2000-01-0966
- Access Restriction:
- Restricted for use by site license