My Account Log in

1 option

EuroSID-I Rib Module Performance and Evaluation Safety and Biomechanics CAE Development Dept. Advanced Vehicle Technology Ford Motor Company

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Sundararajan, S., author.
Conference Name:
International Congress & Exposition (1999-03-01 : Detroit, Michigan, United States)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 1999
Summary:
The aim of this study was to understand the behavior of Eurosid rib module and its components under different impact conditions. This was achieved by impacting the single rib module at two different velocities of 7.6m/s and 10.8m/s at three impact angles of 0, +30 and -30 deg corresponding to each velocity. All tests were done using a 1.86 kg (4.1 lbs), 152 mm (6) circular impactor on the Monterey facility (Linear impactor) and some of the tests were filmed at 5000 fps. Tests were also done with and without tuning spring to assess its contribution to the total rib response. The hydraulic damper and damper spring were dynamically tested at different velocities to obtain their individual characteristics of force-velocity and force-deflection respectively. Static force-deflection characteristics of all the four tuning springs and damper spring were also obtained. The results of single rib tests @ 0 deg were compared with the CAE models currently available in MADYMO-3D and RADIOSS. A summary and discussion of the results of these tests has been presented followed by the conclusions and recommendations. The static and dynamic response of the damper spring was almost same. The absence of tuning spring increased the peak rib deflection in 0 deg impact, but there was no significant difference at other impact angles. The peak rib deflection was the highest for 0 deg impact followed by -30 deg and +30 deg. The hydraulic damper displacements from the tests and models did not correlate well. Maximum rib deflection from RADIOSS and tests correlated well, while the MADYMO result was higher than the tests
Notes:
Vendor supplied data
Publisher Number:
1999-01-1334
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides