Application of Micro-Perforated Panels to Attenuate Noise in a Duct University of Kentucky
- Format:
- Conference/Event
- Author/Creator:
- Liu, J., author.
- Conference Name:
- SAE 2007 Noise and Vibration Conference and Exhibition (2007-05-15 : St. Charles, Illinois, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2007
- Summary:
- The sound attenuation performance of microperforated panels (MPP) with adjoining air cavity is demonstrated. First of all, simulated results are shown based upon Maa's work investigating the parameters which impact MPP performance [1]. It is shown that the most important parameter is the depth of the adjoining cavity. Following this, an experimental study was undertaken to compare the performance of an MPP to that of standard foam. Following this, two strategies to improve the MPP performance are implemented. These include partitioning the air cavity and having a cavity with varying depth. Both strategies show a marked improvement in MPP attenuation